Celling Technologies Logo.jpg Art 21™ BMC


1. Draw patient sample using a collection syringe
a. Harvest bone marrow b. Mix marrow with anticoagulant
c. Present Art 21 BMC to sterile field Art 21 BMC packaging

   ResQ Celling Technologies 003.jpg

2. Transfer bone marrow to the Art 21 BMC device
a. Unscrew and reserve the clear cap located on the top port.
b. Remove the caps from the clot filter. Connect the filter to the Art 21 BMC device.
c. Connect the collection syringe to the clot filter, and then slowly transfer the sample.
d. Close the top port using cap from step 1.
   ResQ Celling Technologies 010.jpg   ResQ Celling Technologies 013.jpg

3. Spin and Re-suspend
a. Load Art 21 BMC into the centrifuge. Use counter balance if needed.
b. Centrifuge for 12 minutes at 3200 RPM.
c. When the spin cycle is completed, transfer the Art 21 BMC to the processing tray.
d. Attach the harvesting syringe to side port. Press the Start button.

  DSC00807_edited.jpg DSC00809_edited.jpg

4. Extraction and Transfer
a. When blue and green lights start blinking, draw 3 mL.
b. When blue light is solid and green light is blinking, draw another 3 mL.
c. Remove syringe and present to sterile field.
d. Attach transfer tubing and transfer cell concentrate.

DSC00815_edited.jpg DSC00815_edited.jpg  

Art 21 BMC
Instructions for Use
Intended Use
The Art 21 BMC is intended to be used in a clinical laboratory or intraoperatively at the point-of-care for the preparation of a cell concentrate from bone marrow.
Summary and Principles
Bone marrow is drawn from the patient and mixed with anticoagulant. The bone marrow is transferred to the Art 21 BMC device. The device is loaded into a centrifuge and spun at 3200 RPM for 12 minutes. After centrifugation, the device is then loaded onto a processing tray. The bone marrow concentrate is collected with a sterile syringe and then presented to the sterile field. The transfer tubing and syringe provided are used to transfer the concentrate back to the sterile field.
CAUTION: Federal law restricts this device to sale and use by or on the order of a physician, or to a clinical laboratory; and use is restricted to by or on the order of a physician.
The Art 21 BMC is a single-use disposable device. Do not reuse or re-sterilize. Follow manufacturer instructions for utilization of the centrifuge. Do not use after the expiration date. Do not use the contents if this kit is opened or damaged. The physician must be thoroughly familiar with the equipment and the surgical procedure prior the utilization of the device. The patient is to be made aware of general risks associated with treatment and the possible adverse effects.

Material Required
Material Provided
Art 21 BMC kit – Part # 8-4358
• Art 21 BMC device (capped)
• Clot filter (capped)
• 10cc syringe (capped)
• Harvesting tubing with female connectors at both ends (capped)
Material not provided but available from Celling Technologies
• Art 21 BMC Centrifuge – Part # 8-4361
• Processing tray – Part # 8-4363
• System Cart – Part # 8-4362
Art 21 BMC is sterilized by gamma radiation. Do not re-sterilize. All products provided are sterilized and packaged by the manufacturer. All items are sterile if the package is undamaged or unopened.
Specimen Collection and Preparation
Appropriate specimens should be collected and transported according to the establishment protocols. Use standard transfusion guidelines for clinical use of the cell concentrate.
ThermoGenesis Corp.
2711 Citrus Road, Rancho Cordova, CA 95742
USA Phone number 1-800-783-8357
Authorized European Representative
Medical Device Safety Service, Schiffgraben 41, 30175 Hannover
Germany Phone number (+49)-511-6262 8630

MDD Safety and Informational Symbols



Potentially biohazardous material

Sterilized by irradiation

Single use only

Lot number

Expiration date


Indicates authorized representative for Res-Q 60 in the European Union

ThermoGenesis Corp. warrants that all reasonable care has been used in the manufacture of this disposable. However, as a result of biological differences in individuals, no product is effective under all circumstances. Because of this fact and since ThermoGenesis Corp. has no control over conditions under which disposable is used, diagnosis and physical and biological characteristics of the patient, methods of administration or its handling after the disposable leaves ThermoGenesis Corp. possession, ThermoGenesis Corp. does not warrant either product is effective. ThermoGenesis Corp. while reiterating the invitation to strictly follow instructions for use in this manual and take all precautions necessary for proper administration of the same, points out that ThermoGenesis Corp. shall not be liable for any incidental or consequential loss, damage, or expense arising directly from use of disposable. ThermoGenesis Corp. will replace only those disposables that it deems were defective at time of shipment. The above is exclusive and in lieu of all other warranties, expressed or implied, written or oral, including, but not limited to, any implied warranties of merchantableness or fitness. No representative, dealer, distributor, or intermediary of ThermoGenesis Corp. is authorized to change any of the foregoing or assume any additional liability or responsibility in connection with this disposable. 

  C E    0197                 37-00-312 Rev. A Effective Date: xx/xx/xx

The ResQ BMC is intended to be used in a clinical laboratory or interoperatively at the point-of-care for the preparation of a cell concentrate from bone marrow.




Rapid Processing

  1.  Rapid turn around of cells to patient

Simple Procedure

  1.  Easy to learn and operate
  2.  Not technique dependent

High Cell Recovery

  1.  Can recover >80% of MNC’s in 6 cc’s of final product (>90% at 10cc’s)

Flexible Final Volumes

  1.  Can harvest anywhere from 3 to 10 cc’s of final product based upon application

Packaged for Sterile Field

  1.  Easily facilitate delivery of cells to the sterile field

Minimally Manipulated Processing

  1.  Assigned class 1  status by the FDA (low risk).

Complete System

  1.  Reliable system components engineered to work together seamlessly